Filter Results By:

Products

Applications

Manufacturers

Test Systems

group of interoperable devices whose integration perform a common test purpose.

See Also: Systems, Equipment, System Integrators, System Test, System Integration


Showing results: 3046 - 3060 of 5294 items found.

  • PXI Precision Resistor Module 18-Channel, 1 to 470

    40-297-014 - Pickering Interfaces Ltd.

    This 18-channel PXI Precision Resistor Module provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-297 series is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems. It is particularly well suited to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.

  • Solar Cell I-V Characterization System

    VS6821 - Industrial Vision Technology Pte Ltd.

    This system provides cell manufactures and laboratories a new way in testing and measuring photovoltaic cells. Integrated with Steady-State Solar Simulator, it provides complete coverage of testing parameters and measurement requirements by most international standards. Its test methods, procedure & equipment are IEC 60904 compliant. Calibration of reference cell is performed at Fraunhofer ISE in Germany, and is traceable to PTB.

  • LXI High-Density Matrix

    Pickering Interfaces Ltd.

    Our LXI High-Density Modules are single and double pole matrices available in a wide range of configurations including versions with the added flexibility of dual analog bus. These high-density matrices are ideal for signal routing in large automatic test equipment (ATE) systems and are suitable for applications where a simple start-up process is required and for applications requiring control over large distances.

  • Salt Spray and Fog Chamber

    SS30 - Bemco Inc.

    Bemco's Standard SS30 Salt Spray and Fog chamber meets all standard military, commercial, and ASTM salt fog corrosion and humidity corrosion tests. The SS30 is currently in redesign to incorporate a clear - see through top with the same advanced features of the previous fiberglass system. This chamber has a workspace of 48-inches wide by 36-inches high by 30-inches deep.

  • Yarn Count Tester

    TESTEX Testing Equipment Systems Ltd.

    Yarn Count Testing Machine, automatically calculates count systems used for sliver, roving and yarn, and can also be used for fabric yield. Yarn Count Tester consists of an accurate electronic balance with a capacity of 400g or 200g x 0.001g and built-in calculating program. Please contact us if you want to know more about yarn count test method.

  • PXIe-1073, 5-Slot (3 Hybrid Slots, 2 PXI Express Slots), Up to 250 MB/s PXI Chassis

    781163-01 - NI

    PXIe, 5-Slot (3 Hybrid Slots, 2 PXI Express Slots), Up to 250 MB/s PXI Chassis - The PXIe‑1073 is designed for a wide range of test and measurement applications and provides an integrated MXI‑Express controller. The chassis features compact, rugged packaging as well as acoustically quiet operation, which makes it ideal for both portable and desktop systems.

  • Drop Weight Impact Testing Machine

    DWTT Series - Jinan Testing Equipment IE Corporation

    DWTT Drop Weight Impact Testing System is suitable for drop weight tear test of various kinds of ferrite, especially for the test of DWTT for pipeline steel as ASTM-E 436, API-RP 5L3, ASTM-E 208 and DIN EN 10274. DWTT has integrated mechanical, electrical, and automatic control technology, and achieved full automation of feeding, hammer lifting impact, and fracture specimen collection. The load frame has a four-column design, features in stable supporting structure, rigid, dual sliding rails. The Drop Weight Drop Weight Tester is equipped with positioning mechanism, anti-dumping mechanism, safety mechanism, hydraulic buffer devices and security guard net. The impact energy is determined by the lifting height and configuration of different net weights. DWTT Drop Weight Impact Testing System is the essential quality control equipment for pipeline manufacturers, steel mills, iron and steel enterprises, and is also widely used for research institutes.1. Buffer device is equipped to avoid the second impact and absorb the residual energy after breaking the specimen so as to prevent the weigher and anvil from destroying. The installation of safety mechanism, buffer device, and security guard net will effectively secure the testing machine and its operation to extend its life.2. Configuration of the specimen-feeding system, anti-second impact device, and specimen centering mechanism will guarantee a quick, accurate and reliable test.

  • Integrated Development Environment for the Creation and Execution of IEEE1641 Test Programs

    SigBase - Spherea Technology Ltd.

    SigBase is an Integrated Development Environment for the creation and execution of IEEE 1641 test programs. It supports the development of tests using flow-charting techniques and the graphical design of signals using newWaveX. It includes fully integrated compilation and signal path allocation software that determines the appropriate instrument and switch path for each signal and test. The run-time system, which is also available as a separate product for use on multiple test stations, controls the operation of the ATS and can provide test results in ATML format.

  • Relaying Current Transformer Analyser

    Eltel Industries

    *Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.

  • New Car 6v Battery Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery.3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish.

  • New Car 24v Battery Tester With Printer

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery.3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish.

  • Moving Die Rheometer

    SG-S05A - Jinge Testing Machine Co.,Ltd

    It tests the feature about vulcanization and searches for the best suitable vulcanization time.It adopts digital intelligent temperature-controller to adjust and sets easily.Its stability, reappear and accuracy is better than the general rotor rheometer.The microcomputer uses import CMOS chip which has high dependability.It draws、calculates and prints automatically,and has copy or blowwing up function. It adopts computer-control and interface to collect、store or deal with data and print test result .This machine's function is better than other types and shows high automatization features. It has functions about curve-comparing and blow up.It uses series of windows operation system flat and graphical software operation interface.The data is dealed with much truly.The user's test operation becomes faster, flexibly and protect conveniently.

  • 12V Automatic Battery and 12/24V Electrical System Analyzer

    6044 - Associated Equipment Corp.

    • Easy-to-read LED voltmeter and ammeter• 500 amp safety clamps with “Flexi-Spring” and patented side terminal adapters• Separate 6 ft. high impedance test leads with alligator clips for tight spots• Cart / Printer can be purchased separately – Cart Model 6038C, Printer Model 6041• Automated testing of Batteries, Alternators, & Starters• Max/Min of Current and Voltage• Microprocessor based control board protected from reverse connections• Testing of 12V and 24V electrical systems• Test all types of batteries • Ideal for testing remotely mounted batteries accurately• Automated 500A variable load tester• INCLUDES: Model 6043 1000 Amp AC/DC Inductive Amp Clamp for checking starter draw or parasitic drain test, also can be used with conventional multi-meters• Made in USA of US and Global Components

  • Full Band Noise Figure and Gain Test Extenders

    STG-06-S1 - ERAVANT

    Full band noise figure and gain test extenders are offered to extend noise and gain measuring capabilities up to higher millimeterwave frequency ranges. These extenders are designed to interface with noise and gain test systems that have an input IF of 10 MHz to 1.6 GHz, such as the industry standard Keysight 8970A/B, N8975A and Maury MT 2075B. The noise figure and gain test extenders include a high-performance, solid-state noise source (STZ series) and a full waveguide down converter (STC series), which consists of a Faraday isolator (STF series), full band mixer (SFB series), frequency multiplier, and IF amplifier. A frequency source with an output signal in the frequency range of 10 to 20 GHz is required as a local oscillator for the down converter. The noise source is automatically powered on and off by the noise figure meter.

  • Wire Test Unit

    McGan Technology

    The Wire Testing Unit (WTU) is used in conjunction with the MMPD-8K kit or the MM5KV Kit purchased with the optional HV Red Wire and is used to easily test the continuity of electrosurgical cables used to connect the electrosurgical generator either to the active handpiece (e.g. laparoscopic instruments or forceps) or to the return electrode which completes the circuit between the generator and the patient. If the conductor is broken without damage to the cable’s jacket it can remain unseen and could be put into use for the electrosurgical operation causing the system to not properly function. By using the WTU you can test to ensure that the cables have continuity prior to actual usage in the operating room. This does not preclude the other tests that should be performed on these cables such as visually examining the cable for jacket damage including cracks, pinholes and abrasions and manually flexing the cable.

Get Help